Home > 제품소개 > TEST & MEASUREMENT (광센서 및 측정기) > Autocorrelator > GECO

GECO
  • Measures pulse duration in 10 fs – 10 000 fs range
  • Measures wavelengths down to 500 nm and up to 2000 nm
  • Compact and portable design
  • Pulse-analysis software for pulse duration measurements
#1 : Autocorrelator (Geco).pdf
#2 : Geco Image 1.bmp
#3 : Geco Image 2.bmp
#4 : Geco Dimension.jpg
Operation of Autocorrelator is based on noncollinear second harmonic generation in a nonlinear crystal, producing an intensity autocorrelation signal directly related to the input beam pulse duration. One arm of the fundamental pulse is delayed by means of a high-resolution 5-phase stepping motor, at 3 fs for full step this resolution can be further enhanced up to ten times by means of step division integrated into our electronics and software.

COMPACT SCANNING AUTOCORRELATOR FOR PULSE DURATION MEASUREMENT

  • Measures pulse duration in 10 fs – 10 000 fs range
  • Measures wavelengths down to 500 nm and up to 2000 nm
  • Compact and portable design
  • Pulse-analysis software for pulse duration measurements
Operation of Autocorrelator is based on noncollinear second harmonic generation in a nonlinear crystal, producing an intensity autocorrelation signal directly related to the input beam pulse duration. One arm of the fundamental pulse is delayed by means of a high-resolution 5-phase stepping motor, at 3 fs for full step this resolution can be further enhanced up to ten times by means of step division integrated into our electronics and software.

The beam to Autocorrelator is directed with the periscope which can be arranged in either polarization-maintaining or polarization-rotating setup, allowing easy measurements of vertically or horizontally polarized pulses. The beam is then split by a broadband metallic beamsplitter, and both beams are directed to a concave mirror, which focuses and combines the beams into a nonlinear crystal, producing a sum-frequency signal of the two beams. Intensity of the generated sum-frequency is directly related to the temporal overlap between the two fundamental pulses. By varying the timing difference with a stepping motor, we can acquire a full intensity autocorrelation trace of 10 fs to 10 ps pulse duration.
There are four filters and two nonlinear crystals available to cover the full 500nm to 2000nm range. Filters are placed on an easily changeable wheel with magnetic fixing.

The Autocorrelator set consists of the following:
  • Periscope to direct the beam into the optical unit
  • Optical unit with beam splitter and combiner into the nonlinear crystal, motorized delay line and filters
  • Two nonlinear crystals, depending on the model
  • A fast pulsed photodiode for up to several kilohertz repetition rates or a DC photodiode for higher repetition rates and increased sensitivity
  • Electronics unit with 1 stepper motor driver and 14 bit pulsed/DC photodiode channels

    GECO models*

    Model

    Operation wavelength, nm

    AC1F1

    500-2000

    *Non-standard models available on request

      Performance specification

    Input wavelength range, nm

    500 2000

    Temporal resolution

    3.33 fs / step, down to 0.3 fs per microstep

    Measurable pulse width, fs

    10 10 000

    Minimum average power of radiation for ~100fs pulse

    >20 mW @ 1 MHz @ <550 nm, >10 mW @ 1 MHz @ >550n

    Detector

    Si photodiode


    Dimensions, mm

    Full dimensions

    188 W x 293 L x 212 H

    Housing

    178 W x 173 L x 57 H

    Beam interception height

    70 - 180

    Weight

    3,7 kg




 